ZONSKY INSTRUMENT CO.,LTD

ZONSKY INSTRUMENT CO., LTD Professional Test Equipment Manufacturer

Manufacturer from China
Active Member
7 Years
Home / Products / Ozone Test Chamber /

Durable Ozone Testing Lab 10 ~ 1000 pphm Ozone Concentration Accuracy

Contact Now
ZONSKY INSTRUMENT CO.,LTD
City:dongguan
Province/State:guangdong
Country/Region:china
Contact Person:MissVivi
Contact Now

Durable Ozone Testing Lab 10 ~ 1000 pphm Ozone Concentration Accuracy

Ask Latest Price
Brand Name :ZONSKY
Model Number :ZY6072-ZN
Certification :ISO9001:2008, CE, SGS, IAF
Place of Origin :DONGGUAN, CHINA
MOQ :1 Set
Price :Negotiable
Payment Terms :L/C, T/T, Western Union
Supply Ability :10 Set / Month
Delivery Time :10 Working Days
Packaging Details :Wooden Case
Standards :ASTM D1149
Test Method :Static & Dynamic
Temperature Range :0℃ ~ 80℃
Airflow Speed :12 ~ 16 mm/s
Gas Flow Rate :20 ~ 70 L/min
Weight :About 220 kgs
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

ASTM D1149 Digital Display Laboratory Ozone Proof Aging Test Chamber

I. Application

Ozone is rare in the atmosphere but a main factor for rubber crack. This product simulates and strengthens the ozone condition in the atmosphere, studies of the law of ozone reacting on rubber, and quickly identifies and evaluates the anti-ozone aging performance and the anti-ozone agent protection efficiency of rubber. Reference standard: GB/T7762-2003 vulcanized rubber or thermoplastic rubber ozone cracking resistance static tensile test, GB/T 2951.21-2008 cable insulation and sheath material general test method, GB/T 11206-2009 rubber aging surface cracking test method, and other relevant standard test methods.

2. Principles and methods

According to the test method and standard, the test method can be divided into "static" and "dynamic". Static means that the sample is stretched and put into the test box for testing. Dynamic means that the sample is placed on the fixture of the test box while stretching, and the fluctuation of stretching is about 5% - 45% of the sample itself.

3. Main technical parameters

3.1. temperature range: 0℃ ~ 80℃

3.2. temperature fluctuation: ±0.5℃ ± 2℃

3.3. ozone concentration accuracy: 10 ~ 1000 pphm ± 10%

3.4. sample rack stretch frequency: 2 R/min (optional)

3.5. airflow speed: 12 ~ 16 mm/s

3.6. test gas flow rate: 20 ~ 70 L/min

3.7. sample rack speed: 360 degree rotating sample rack (rotate speed 1~3 per minute or adjustable)

3.8. internal dimensions: W500 X H600 x D500 mm (W stands for width, H represents high, D represents deep)

3.9. external dimensions: W1100 X H1700 x D1050 mm (W stands for width, H represents height, D represents depth).

3.10. weight: about 220 kgs

3.11. power supply: AC220 ± 5%V /50 ± 0.5Hz

Inquiry Cart 0